{"product_id":"woodpecker-fi-g-gutta-percha-obturation-hot-melting-filing-device-black","title":"Woodpecker Fi-G Gutta-Percha Obturation Hot Melting \u0026 Filing Device - Black","description":"\u003cp\u003eWoodpecker Fi-G Gutta-Percha Obturation Hot Melting \u0026amp; Filing Device - Black\u003c\/p\u003e\n\u003cp\u003eThe Fi-P (Heat \u0026amp; Packing) and Fi-G (Hot Melting \u0026amp; Filing Gun) work in conjunction with each other for the ultimate gutta-percha obturation system for your root canal procedures.\u003c\/p\u003e\n\u003ch2\u003eHow the Woodpecker Obturation System Works\u003c\/h2\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/3z6eOkbg5VM?si=r0zWwAKLrJqhZnEM\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWFLG (Fi-G) Includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"general\"\u003e\n\u003cli\u003e1 x Obturation Gun\u003c\/li\u003e\n\u003cli\u003e1 x Power adapter with cable\u003c\/li\u003e\n\u003cli\u003e1 x Gutta-percha injection needle 23G#24mm\u003c\/li\u003e\n\u003cli\u003e1 x Gutta-percha injection needle 23G #28mm\u003c\/li\u003e\n\u003cli\u003e2 x Gutta-percha injection needles 25G #24mm\u003c\/li\u003e\n\u003cli\u003e2 x Heat insulation hood\u003c\/li\u003e\n\u003cli\u003e1 x Heat insulation sleeve for injection needle\u003c\/li\u003e\n\u003cli\u003e2 x Cleaning brush\u003c\/li\u003e\n\u003cli\u003e1 x Pushing ram\u003c\/li\u003e\n\u003cli\u003e1 x Wrench\u003c\/li\u003e\n\u003cli\u003eInstruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Obturation System - WFLG\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-img-2.jpg\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFi-G Feature Summary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Fi-G Feature Summary\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-img-9.jpg\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Fi-G Feature Summary\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-img-10.jpg\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Fi-G Feature Summary\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-img-11.jpg\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Fi-G Feature Summary\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-img-12.jpg\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003ch2\u003eInstructions for Use\u003c\/h2\u003e\n\u003cp\u003eThe steps below show a typical workflow using a gutta percha obturation pen and obturation gun system. Fi-P is used for heating and packing, and Fi-G is used for thermoplasticized gutta-percha backfill.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Instructions for use for Woodpecker Fi-P and Fi-G obturation system\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-img-13.jpg\" width=\"100%\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"row instructions-sec\"\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e01\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 1 for gutta percha obturation pen\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-1.jpg\"\u003e\n\u003cdiv class=\"inst-txt a\"\u003eAccording to the prepared root canal, choose a proper chief gutta-percha tip.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e02\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 2 for Woodpecker Fi-P heat plugger\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-2.jpg\"\u003e\n\u003cdiv class=\"inst-txt b\"\u003eChoose proper tip for Heating and Packing Instrument, place the tip into the root canal and keep it 4-7mm away from the apical foramen, and use a pad to mark the length. At the same time, choose a plugger of the same size.\u003cbr\u003e\u003cimg alt=\"Fi-P instrument type for Woodpecker obturation system\" class=\"img-responsive inst-type\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-inst-fi-p.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e03\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 3 for gutta percha pen obturation\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-3.jpg\"\u003e\n\u003cdiv class=\"inst-txt c\"\u003eDip the sealing material with the chief gutta-percha tip, and then put that gutta-percha tip into the root canal.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e04\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 4 using Fi-P Woodpecker obturator pen\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-4.jpg\"\u003e\n\u003cdiv class=\"inst-txt d\"\u003ePut the tip of Heating and Packing Instrument into the root canal, press heating button for heating, cut off the redundant part of gutta-percha and take it out.\u003cbr\u003e\u003cimg alt=\"Fi-P instrument type for heating and packing\" class=\"img-responsive inst-type\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-inst-fi-p.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e05\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 5 for Woodpecker heat plugger and packing pen\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-5.jpg\"\u003e\n\u003cdiv class=\"inst-txt e\"\u003ePut the tip into the root canal, press heating button for heating, and push the tip to soften the gutta-percha until the tip reach a place where is 4-7mm away from the apical foramen. (Do not heat up for more than 3s. Meanwhile, keep the tip moving while heating and avoid heating at a certain part for a long time, or it is likely to scalding the root canal.)\u003cbr\u003e\u003cimg alt=\"Fi-P instrument type for warm vertical compaction\" class=\"img-responsive inst-type\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-inst-fi-p.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e06\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 6 for gutta percha obturation pen\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-6.jpg\"\u003e\n\u003cdiv class=\"inst-txt f\"\u003eRelease the heating button to stop heating, but keep pressing the gutta-percha in the root canal with tip for about 10s.\u003cbr\u003e\u003cimg alt=\"Fi-P instrument type for packing\" class=\"img-responsive inst-type\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-inst-fi-p.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e07\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 7 for Woodpecker fi-p heat and packing pen\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-7.jpg\"\u003e\n\u003cdiv class=\"inst-txt g\"\u003ePress heating button for about ls, and rapidly take out the gutta-percha 4-7mm away from the apical foramen.\u003cbr\u003e\u003cimg alt=\"Fi-P instrument type for heating\" class=\"img-responsive inst-type\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-inst-fi-p.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e08\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 8 using plugger with gutta percha\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-8.jpg\"\u003e\n\u003cdiv class=\"inst-txt h\"\u003eUse plugger to impact the gutta-percha in the root canal.\u003cbr\u003e\u003cimg alt=\"VP instrument type for compaction\" class=\"img-responsive inst-type\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-inst-vp.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e09\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 9 for Fi-G obturation gun backfill\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-9.jpg\"\u003e\n\u003cdiv class=\"inst-txt i\"\u003eGet the needle of Hot Melting and Filling Gun touch the surface of gutta-percha in the root canal, and stay there for 3s to soften the gutta-percha.\u003cbr\u003e\u003cimg alt=\"Fi-G instrument type for obturation system\" class=\"img-responsive inst-type\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-inst-fi-g.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e10\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 10 for obturation gun injection\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-10.jpg\"\u003e\n\u003cdiv class=\"inst-txt j\"\u003eInject the melted gutta-percha into the root canal, and withdraw the needle at the same time. (Do not fully fat the root canal at only one time. It is recommended to fill it in 3 times, or a single injection should not exceed 4mm.)\u003cbr\u003e\u003cimg alt=\"Fi-G instrument type for gutta percha obturation\" class=\"img-responsive inst-type\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-inst-fi-g.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e11\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 11 compacting injected gutta percha\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-11.jpg\"\u003e\n\u003cdiv class=\"inst-txt k\"\u003eUse plugger to impact the injected gutta-percha in the root canal.\u003cbr\u003e\u003cimg alt=\"VP instrument type for compaction\" class=\"img-responsive inst-type\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-inst-vp.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-12 inst-item\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-1 inst-number\"\u003e12\u003c\/div\u003e\n\u003cdiv class=\"col-sm-11 inst-text\"\u003e\n\u003cimg alt=\"Instructions for use step 12 repeat obturation steps\" class=\"inst-img\" src=\"https:\/\/www.physicsforceps.com\/images\/obturation-system-instructions-12.jpg\"\u003e\n\u003cdiv class=\"inst-txt l\"\u003eRepeat Step 9 to Step 11 until the root canal filling is finished.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Woodpecker","offers":[{"title":"Default Title","offer_id":48017314676984,"sku":"WFLG","price":679.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/1309\/9512\/files\/Obturation-System-img-5-1000x1000.jpg?v=1771968551","url":"https:\/\/www.golden-dent.com\/products\/woodpecker-fi-g-gutta-percha-obturation-hot-melting-filing-device-black","provider":"GoldenDent","version":"1.0","type":"link"}